ASTM C204 PDF

      No Comments on ASTM C204 PDF

Fineness of Hydraulic Cement by Air Permeability Apparatus. ASTM C 11 Standard Test Methods for Fineness of Hydraulic Cement by Air Permeability Apparatus – Download as PDF File .pdf), Text File .txt) or read. ASTM C Standard Test Methods for Fineness of Hydraulic Cement by Air- Permeability Apparatus. standard by ASTM International.

Author: Voodoocage Nikosar
Country: Albania
Language: English (Spanish)
Genre: Business
Published (Last): 28 November 2018
Pages: 466
PDF File Size: 20.15 Mb
ePub File Size: 17.9 Mb
ISBN: 354-1-64051-952-3
Downloads: 85894
Price: Free* [*Free Regsitration Required]
Uploader: Akinogore

Mercury, or its vapor, has been demonstrated to be hazardous to health and corrosive to materials.

ASTM C Fineness of Hydraulic Cement | CTLGroup

Active view current version of standard. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use.

However, the atsm should exercise judgement in determining its suitability with regard to fineness measurements of cements with densities, or porosities that differ from those assigned to Standard Reference Material No. Although the test method may be, and has been, used for the determination of the measures of fineness of various other materials, it should be understood that, in general, relative rather than absolute fineness values are obtained.

Aztm Documents purchase separately The documents listed below are referenced within the subject standard but are not provided as part of the standard.

This abstract is a brief summary of the referenced standard. The disk shall be constructed of noncorroding metal, and shall fit the inside of the cell snugly. This test method covers determination of the fineness of hydraulic cement, using the Blaine air-permeability apparatus, in terms of the specific surface expressed as total surface area in square centimetres per gram, or square metres per kilogram, of cement. Work Item s zstm proposed revisions of asgm standard.

  EL PENECA PDF

Work Item s – proposed revisions of this standard. Two test methods are given: The Blaine air-permeability apparatus consists essentially of a means of drawing a definite quantity of air through a prepared bed of cement of definite porosity.

ASTM C Standard

The plunger shall be constructed of austenitic stainless steel and shall fit into the cell. Link to Active This link will always route to the current Active version of the standard. The manometer shall be filled to the midpoint line with a nonvolatile, nonhygroscopic liquid of low viscosity and density. Although the test method may be, and has been, used for the determination of the measures of fineness of various other materials, it should be understood that, in general, relative rather than absolute fineness values are obtained.

Historical Version s – view previous versions of standard Work Item s – proposed revisions of this standard Translated Version s: Referenced Documents adtm separately The documents listed below are referenced within the subject standard but are not provided as part of the standard.

The timer shall have a positive starting and stopping mechanism. The filter paper disks shall be circular, with smooth edges, and shall have the same diameter as the inside of the cell. It is the responsibility of the user of this standard to establish appropriate safety c2004 health practices and wstm the applicability of regulatory limitations prior to use. When the specific surface values determined by an automated apparatus are to be used for acceptance or rejection of cement, the method used shall comply with the qualification requirements.

ASTM C204 – 17

ASTM does not give any warranty express or implied or make any representation that the contents of this abstract are accurate, complete or up to date. Test Method A is the Reference Test Method using the manually operated standard Blaine apparatus, while Test Method B permits the use of automated apparatus that has in accordance with the qualification requirements of this test method demonstrated acceptable performance.

  ALVANIA RL3 PDF

Historical Version s – view previous versions of standard. The automated test method shall employ apparatus designed either on the principles of the Blaine air-permeability method or apparatus based on the air-permeability principles of the Lea and Nurse method. The permeability cell shall consist of a rigid cylinder, constructed of austenitic stainless steel.

Link to Active This link will always route to the current Active version of the standard. It is informational only c240 not an official part of the standard; the full text of the standard itself must be referred to for its use and application. Test Method A is the Reference Test Method using the manually operated standard Blaine apparatus, while Test Method B permits the use of automated apparatus that has in accordance with the qualification requirements of this test method demonstrated acceptable performance.

The calibration of the air permeability apparatus shall be made using the standard reference material. Caution should be taken when handling mercury and mercury containing products.

However, the user should exercise judgement in determining its suitability with regard to fineness measurements of cements with densities, or porosities that differ from those assigned to Standard Reference Material No.

When standardization is required in order to achieve agreement between test method A and test method B, the apparatus shall be standardized according to the requirements prescribed.

Two test methods are given: The U-tube manometer shall be constructed according to the design indicated.