ASTM C42 FREE PDF

      No Comments on ASTM C42 FREE PDF

This standard is issued under the fixed designation C42/C42M; the number . of core test results.2 and that is free of is the individual responsible for analysis or. ASTM C42/C42M () Standard Test Method for Obtaining and Testing Drilled ASTM International, West Conshohocken. Free SCIRP Newsletters>> . ASTM C Potential Resistance to Degradation. In-situ Tests . Determine time from start until no free water is on ASTM C42, Coring, 3 cores/5, sf.

Author: Tojajinn Brara
Country: Montserrat
Language: English (Spanish)
Genre: Health and Food
Published (Last): 12 June 2011
Pages: 94
PDF File Size: 1.65 Mb
ePub File Size: 17.17 Mb
ISBN: 468-2-22331-221-1
Downloads: 75639
Price: Free* [*Free Regsitration Required]
Uploader: Moogukazahn

CObtaining and Testing Drilled Cores and Sawed Beams of Concrete

SI units are shown in brackets. If the ratio of the length to the diameter of the core specimen exceeds 2. Sampling and sample preparation requirements are given to ensure that dimensional requirements are met and that the specimens are comprised of intact sound concrete as free of flaws as the particular structure will allow. The saw shall have a diamond or silicon-carbide cutting edge and shall be capable of cutting specimens which conform to the prescribed dimensions, without excessive heating or shock.

C 39 with the addition of the following information: Current edition approved Feb. When preparing strength test specimens from samples of hardened concrete, samples that show defects or samples that have been damaged in the process of removal shall not be used.

Measure the lengths of such cores in accordance with Test Method C Ends are not to be capped. Originally published as C 42 — 21 T.

Core specimens with length-to-diameter ratios less than 1. Combining values of the two units may result in nonconformance.

Active Risk Management

Additionally, this method may be used to provide strength information on older structures. BoxFarmington Hills, MI This standard has been approved for use by agencies of the Department of Defense. Parte 1 de 2 Designation: Cap or grind the cores, and test them within 48 h of receipt. Do not use specimens with projections or depressions greater than 0.

  MAHA PRAJNA PARAMITA SUTRA PDF

The acceptance criteria for core strength is to be established by the specifying authority. Average values are given in the table. Measure core diameters to the nearest 0. Determine the average diameter by averaging two measurements taken at right angles to each other about the midheight of the specimen.

Aastm values stated may not be exact equivalents, therefore each system must be used independently of the other. If necessary, saw the ends of the specimens until the following requirements are met: NOTE 3—Correction factors depend on various conditions such as moisture condition, strength level, and elastic modulus.

When grinding or atsm of the bearing surfaces is. Length of Drilled Cores 6. When the line of contact is not straight or contains projections or depressions having heights or depths greater than 0. Core diameters less than 3. The preferred length of the capped specimen is between 1.

Last previous edition C 42 — The ends shall be sawed or ground to tolerance or capped in accordance with capping procedures for hardened concrete specimens of Practice C If this is not practical, removal of concrete can proceed if the cut surfaces do not display erosion of the mortar and the exposed coarse aggregate particles are embedded firmly in the mortar. NOTE 2—Prior to capping, the density of a core may be determined by weighing it and dividing it by the volume calculated from the average diameter and length, or by any other standard method for determining density.

Thus, these factors should be applied to high-strength concrete with caution. The relationship is affected by many factors such as the strength level of the concrete, the in-place temperature and moisture history, and the strength gain characteristics of the concrete. Cores for Compressive Strength 7.

  JBL LSR4326P MANUAL PDF

NOTE 1—It is not possible to specify a minimum age when concrete is strong enough to withstand damage during removal, because the strength at any age depends on the satm history and strength grade of the concrete.

In-place test methods may be used to estimate the level of strength development prior to attempting removal of concrete samples. Livro sobre Cimento Portland e Concreto. A specimen taken perpendicular to a vertical surface, or perpendicular to a surface with a batter, shall be taken from near the middle of a unit of deposit when possible and not near formed joints or obvious edges of a unit of deposit.

If time permits, the concrete should not be removed before it is 14 days old.

Significance and Use 3. Therefore, results of two properly conducted tests on cores sampled from the same hardened concrete where a single test is defined asmt the average of two observations coreseach made on separate adjacent drilled 4 in.

ASTM C42-C42M – 04

They are applicable to both dry and wet concrete for strengths between and psi [14 to 42 MPa]. For strengths above ftee [70 MPa], test data on cores show that the correction factors may be larger than the values listed above. When capping is employed the caps shall be as thin as practicable and shall be formed of high-strength gypsum plaster. ACI provides core strength acceptance criteria for new construction. A number in parentheses indicates the year of last reapproval.

A superscript epsilon e indicates an editorial change since the last revision or reapproval.

It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.