ASTM D TESTING FIXTURE. CLIMBING DRUM PEEL FOR ADHESIVES. 1. ASTM D Testing Fixture. This procedure is useful for the determination of. ASTM D Testing Fixture. This procedure is useful for the determination of the peel resistance of adhesive bonds adhering a relatively flexible and adhering. Industries (F.Z.E.) to determine the adhesioII and tensile strength of their 3 III11 AluboId Metal. Conposile Material. The average test results are.

Author: Faektilar Vogul
Country: Albania
Language: English (Spanish)
Genre: Travel
Published (Last): 28 May 2006
Pages: 400
PDF File Size: 1.76 Mb
ePub File Size: 1.43 Mb
ISBN: 740-2-46152-750-8
Downloads: 75717
Price: Free* [*Free Regsitration Required]
Uploader: Akilkree

ASTM D1781 TESTING FIXTURE

Standards can be obtained from appropriate standard authorities. Due to the errors in the peel force caused by the force to lift the drum and force to bend the flexible adherand around the drum, this standard is less popular than other peel testing standards and is typically used for comparative testing in process control and process optimization situations.

Validating the specifications, asm and safety of your raw materials, products and assets.

If test results are to be used only for comparative test to test purposes, then this error testing is not necessary because the errors are the same in each test and therefore negate each other. For ASTM D, we would configure a small capacity satm cell 10 or 25 pound for this low force peel test. Direct comparison of different adhesives or processes can only be made when specimen x1781 and test conditions are identical.

If you would rather see the data in real-time and study the peel interface at the same time, we would provide you with our XyLive Software. These errors can both be compensated out of the test by running the test on one or asstm dummy specimens which have the same flexible adherand but no adhesive.

A test can also be performed on a dummy specimen, which is the same as a test specimen but has no adhesive, in order to quantify the force errors in the test setup.

Global Reach Intertek is the industry leader with over 42, people ast, 1, locations in over countries. For laminates, 25 mm [1 in] wide between saw kerfs by at least mm [10 in].

  DESPRE PSIHANALIZA SIGMUND FREUD PDF

We also recommend that you purchase the ASTM Qstm standard and follow it closely to achieve the best results.

Have a question about conducting the test for this standard? Assurance Testing Inspection Certification.

Whether your business is local or global, we can ensure your products meet quality, health, environmental, safety, and social accountability standards for virtually any market around the world.

Auditing Consulting Sourcing Training.

ASTM D1781

From climbing drum peel results the following calculations can be made: Formally confirming that your products and services meet all trusted external and internal standards. Samples need to be thick enough not to bend during test. Certification Formally confirming that your products and services meet all trusted external and internal standards.

This test method is used to compare adhesion between flexible and rigid adherends, or between flexible facing of a sandwich structure and its core. The peel plot will be an important aspect of data retrieval and therefore we highly recommend our XyPlot software. Force range of 5 kN to kN 1, lbf tolbf Adjustable test space The most popular choice for static tension and compression tests These dual column testers are available in both tabletop and floor standing models.

Rated to 5 kN lbf Maximum specimen thicknesses from 24 mm to mm 1 in to 4 in Simple yet strong design can be used for a multitude of tensile applications Works well with flat or round specimens. Give one of our engineers a call today and they can help guide you through the ASTM D test process with the best machine configuration for your requirements. Our engineers are familiar with the ASTM D test procedure and can guide you through the process and help you choose the best equipment.

Historical Version s – view previous versions of standard. Send us a request Need help or have a question? The peel resistance may indicate degree of cure for relatively brittle adhesives. The grips of a Universal Test Machine are initiated at a specified grip separation significant enough to roll the drum upward.

This fixture is made specifically to ASTM D and consists of a flanged drum, flexible loading straps, and specified clamps for holding the test specimen. Testing Evaluating how your products and services meet and exceed quality, safety, sustainability and performance standards.

ASTM D is a standard test to determine the peel resistance of adhesive bonds on products that have a flexible adherand and a rigid adherand surface.

  BATTLESTAR GALACTICA TRIAD CARDS PDF

The P consists of a vertical load frame, an electromechanical actuator, load cell, a tocuhpad test controller, XY test software and a climbing peel drum fixture. The values given in parentheses are for information only.

Forces up to 10 kN 2, lbf Low force tabletop systems Modular series of five frame options with adjustable test space Affordable testing option for tension, compression, bend, peel and much more. A 10 lb load cell can be calibrated to axtm 0. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. Through our network of over 43, people in 1, laboratories and offices in countries, Intertek atm quality and safety solutions to a wide range of industries around the world.

For this test, our engineers also recommend a GG manual vice grip. Link to Active This link will always route to the current Active version of the standard. When a relatively brittle adhesive is used, the peel resistance can often give an indication of the degree of cure, that is, higher values than normally realized may indicate an incomplete cure.

Standard Test Method for Climbing Drum Peel for Adhesives – ASTM D

This standard can also be used for testing dd1781 sandwich structure and its core by pulling the facing off the sandwich assembly. Evaluating how your products and services meet and exceed quality, safety, sustainability and performance standards. We are confident that we have what you are looking for. This test method may be used to determine comparative rather than fundamental measurements of adhesion and is particularly suitable for process control, some examples of which are listed.

This test method is particularly sensitive to adherend surface preparation and is of value where the adhesive is used in conjunction with a primer. Enabling you to d17811 and mitigate the intrinsic risk in your operations, supply chains and business processes.